Project Description

aquaSub is a groundwater control system that is capable of integrating different types of probes, giving great flexibility to make the necessary measurements for each application.

It is marked by its communication system GSM / GPRS, which minimizes costs and improves communication.

Structure System

aquaSub : groundwater control unit.
• UCR OPC Driver: communications management software. All information sent and received by aquaSub equipment is stored by the UCR OPC Driver and can be managed through any control center using standard OPC communications.

The main advantage of the aquaSub equipment is the low cost and ease of installation with the various power modes, GSM / GPRS communication and the equipment flexibility for the integration of different probes.

Operation

The proposed system ensures:

• Monitoring, recording and reporting the level and quality water in aquifers, allowing assessment on available resources, effects of exploitation and detection of pollution episodes.
• Integration of almost all types of probes available on the market, giving it flexibility to meet the needs of each facility and presenting the results in a single front-end communication (OPC Driver UCR) to facilitate the integration of the probes to the operating system.
• Definition of the reading frequency of the various probes independently connected to the computer.
• Transmission of information in real or deferred time, as needed and depending on the feed-in system.
• Reduction of installation costs through power management and communication system.

Noteworthy Characteristics

• Communication GSM/GPRS.
• MODBUS master function for reading multiple probes.
• Analog inputs for reading voltage and / or current probes and power management of them.
• System power management to minimize consumption of the equipment itself and associated probes to maximize the system’s autonomy.
• Versatile Power System with integrated SLA battery charger.
• High data storage capacity.
• 8 years autonomy (see conditions).

Temperature Range: -30ºC à +60ºC
Protection Degree: IP66
External Power (Limited power source)
Nominal : 12 Vdc
Tolerance: +7,2 Vdc … +20 Vdc
Maximum current: 0.5 A
Power Solar Panel
Voltage nominal panel: 12 Vdc
Maximum current load: 150 mA
Nominal voltage battery: 12 Vdc
Float Voltage: 13,8 Vdc
Protections: Reverse polarity, overvoltage and temperature compensation.
Internal Power (Limited power source)
Batteries: 8 Lithium Batteries (4 groups of 7,2V in parallel)
Power Output (Optional)
Nominal voltage/current: 24 Vdc / 100 mA et 5 Vdc / 50 mA
Activation: Set up activation time to minimize consumption.
Protection: Short circuit
Pulse Inputs
No. Meters: 4
Minimum Pulse: 1 ms
Maximum frequency: 65535 pulses / registration period or 10Hz
Cable Maximum length: 100 m
Alarm generation: Set up by overcoming number of pulses
Smart Meters (Optional)
Bus: CZBus (3 hilos, SEL, SDATA, GND)
Frames: A Type
No. Meters: 4
Reading time: 60 segundos
Cable Maximum length: 20 m
Digital Inputs
No.Imputs 8
Filtering period: 1… 60 seconds
Alarm generation: Set up by low level
Analog inputs
No.Inputs: 4
Range: 0…25 mA / 0…10 V
Accuracy : 1 %
Alarm generation: Low and/or high level
Protection: Over current and over voltage to 24Vdc
Valve excitation output
No. Outputs: 4
Configuration: 2 / 3 Wires
Nominal : 9 V / 12 V / 24 V, setup configuration
Maximum current: 500 mA / 0.5 sec
Cable Maximum length: 100 m
Protection: Short-circuit
Communications:
RS232 – 3.3V Menu display / configuration (ANSI)
RS232 – 12V (optional) MODBUS Master
RS485 (optional): MODBUS Slave
USB: (Optional)
Modem GSM / GPRS GSM – MODBUS Protocol (slave)
GSM – (ASCII)
GSM – Menu display/ configuration (ANSI)
GSM – Sending alarms via SMS
GPRS – MODBUS IP Protocol
GPRS – Proprietary Protocol (ASCII)